Suntan Varistor includes Dipped & SMD Types
A Varistor remains non-conductive as a shunt mode device during normal operation when voltage remains well below its "clamping voltage". If a transient pulse (often measured in joules) is too high, the device may melt, burn, vaporize, or otherwise be damaged or destroyed. This (catastrophic) failure occurs when "Absolute Maximum Ratings" in manufacturer's datasheet are significantly exceeded. Varistor degradation is defined by manufacturer's life expectancy charts using curves that relate current, time, and number of transient pulses. A varistor fully degrades typically when its "clamping voltage" has changed by 10%. A fully degraded varistor remains functional (no catastrophic failure) and is not visibly damaged.
Ballpark number for varistor life expectancy is its energy rating. As MOV joules increase, the number of transient pulses increases and the "clamping voltage" during each transient decreases. The purpose of this shunt mode device is to divert a transient so that pulse energy will be dissipated elsewhere. Some energy is also absorbed by the varistor because a varistor is not a perfect conductor. Less energy is absorbed by a varistor, the varistor is more conductive, and its life expectancy increases exponentially as varistor energy rating is increased. Catastrophic failure can be avoided by significantly increasing varistor energy ratings either by using a varistor of higher joules or by connecting more of these shunt mode devices in parallel